RS485 3 click - SN65HVD31 jadaliidese adapter
38-MIKROE-2821
Pamatinformācija
RS485 3 click uses from , a tri-state differential line driver and differential input line receiver. The click is intended to be used as UART to RS422/RS485 communication interface. It is suited for transmitting smaller blocks of data over long distRS485 3 click uses from , a tri-state differential line driver and differential input line receiver. The click is intended to be used as UART to RS422/RS485 communication interface. It is suited for transmitting smaller blocks of data over long distances, using the four-wire bus, allowing for full-duplex communication.
It can be used as a transceiver between UART interface and RS422/RS485 communication bus. RS485 3 click can be used for controlling various building automation systems, light controllers, sensors and many small embedded devices that can all share the same bus, which can stretch up to 254 nodes and up to 1200m in length.
How does it work?
The main feature of the RS422/RS485 interface is that the signals can be transmitted and received at distances up to 1200m by using the so-called twisted pairs - basically, the signal and its inverted copy are sent via the twisted pair wires. Because of the length of the twisted pair, it will unavoidably be exposed to the influence of the EMI. The interferences will appear in both wires of the twisted pair equally, but thanks to the opposite polarity of the signals the wires are carrying, the interferences will get canceled at the differential inputs of the SN65HVD31. This way, greater signal communication distances can be achieved than with the regular UART.
RS422/RS485 only specifies electrical characteristics of the transmitter and the receiver. It does not specify or recommend any communications protocol, only the physical layer. The top layer communication protocol of choice can be used, such as the MODBUS or DMX protocols.
To improve the signal stability, RS485 3 click is equipped with the TVS – transient voltage suppression diodes used to protect the circuit from the static electricity discharges and other types of dangerous electrical discharges, that might occur.
There are four onboard screw terminals (RX+, Rx-, Tx+, Tx-) for connecting RS422/RS485 twisted pair cable, along with two screw terminals (GND) for common ground connection.
TX and RX pins should be used for connecting MCU UART interface. Two resistors (R2 and R5) should be unsoldered if using more than two clicks on the RS422/RS485 bus.
Downloads
Izmēri un svars
Produktu kodi
Pasūtījumiem virs 99 € Photopoint piedāvā bezmaksas piegādi Igaunijas teritorijā. Ieskatieties cilnē „Piegāde”, lai iegūtu precīzāku piegādes cenu aprēķinu.
Jūs varat izvēlēties vēlamo piegādes veidu iepirkumu grozā:
Omniva paku termināls
Jūs varat pasūtīt preces uz jebkuru no Omniva paku termināļiem. Izvēlieties vēlamo termināli iepirkumu grozā. Līdzko sūtījums ieradīsies, Jums tiks nosūtīts SMS ziņojums ar unikālu kodu. Dodieties uz termināli nedēļas laikā, ievadiet kodu un paņemiet savu sūtījumu. Tas ir tieši tik vienkārši!
Omniva paku termināļu adreses skatīt šeit. Omniva kurjera piegāde
Kurjers nogādās Jūsu preces no Photopoint tieši uz Jūsu norādīto adresi. Piegāde tiek veikta darba dienās no 08:00 līdz 17:00. Kurjers Jums piezvanīs pirms ierašanās, tāpēc turiet savu telefonu tuvumā. Lūdzu, pārliecinieties, ka piegādes galamērķī atrodas persona, kas būs ir tiesīga saņemt sūtījumu.